Table 6–1. LCD Message Troubleshooting Table

Displayed Message

Can

User

Correct?

Explanation

Solution

8.5V PWR FAIL*

No

Internal power failure.

Contact your authorized service
representative.

1

15V CTL FAIL*

No

Controller voltage failure.

Contact your authorized service
representative.

1

23.5V CTL FAIL*

No

Controller voltage failure.

Contact your authorized service
representative.

1

48V PWR FAIL*

No

Internal power failure.

Contact your authorized service
representative.

1

ACCESS NULL PTR*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

ACTIVATE LOST

No

Printer detects twinax
protocol communication
errors.

The printer reports the error.

A TO D OVERUN*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

BUFFER OVERFLOW

Yes

Host sends data after the
printer buffer is full. (Serial
interface.)

Check your serial host interface
parameter settings; if necessary,
adjust them so that they match
the settings of the attached host.

BUFFER OVERRUN

Yes

Receive overrun. (Serial
interface)

Check printer serial port
configuration setup. Ensure the
baud rate and data protocol
match both host and printer
settings.

CLEAR PAPER JAM

Yes

No paper motion.

Clear jam and reload paper. If this
message recurs, contact your
authorized service
representative.

1

CLOSE PLATEN

Yes

The forms thickness lever
is open.

Close the forms thickness lever.

COIL HOT

Yes

One or more hammer coils
are hot.

Check printer environment. If too
hot or dusty, relocate printer. May
occur normally on graphically
intense print jobs.

15 COMM CHECK

Yes

Line not active. (Twinax
interface)

Check cable connection.

CTL VOLT FAIL*

No

Controller voltage failure.

Contact your authorized service
representative.

1

DRVR CIR BAD*

No

Hammer coil count test
failed.

Contact your authorized service
representative.

1