Configuration Menus

P–Series Emulation

Control Code 06

Control Code 06 defines the function of ASCII code 06 hex (ACK). You can select

an alternate line spacing of 6, 8 or 10.3 LPI.

Control Code 08

Control Code 08 defines the function of ASCII code 08 hex (BS). You can define

the code to output an elongated character or to output a backspace.

Define CR Code

This option controls the action of the printer when it receives a Carriage Return

code (0D hex) from the host computer. If this feature is enabled, each time the

printer receives a Carriage Return, it inserts an additional Line Feed code (0A

hex) into the data stream. Do not use this feature if the host computer sends Line

Feeds to the printer.

CR = CR does not insert an extra Line Feed after each Carriage Return.

CR = CR + LF inserts an extra Line Feed after each Carriage Return.

The next print position will be print position 1 of the next line.

Auto LF

This option defines the printer actions when print data is received past the forms

width setting.

Enable performs an automatic carriage return and line feed when data

is received past the forms width.

Disable discards any data past the forms width.