Printronix Series 5 User Manual

Page 160

Advertising
background image

Configuration Menus

4–107

Word Length

The Data Bits parameter sets the length of the serial data word. The length of the

data word can be set to 7 or 8 bits, and must match the corresponding data bits

setting in the host computer.

Stop Bits

The Stop Bits parameter sets the number of stop bits in the serial data word.

Either one or two stop bits can be selected. The setting must match the

corresponding stop bit setting in the host computer.

Parity

The Parity parameter can be set for odd parity, even parity, mark, sense, or no

parity. The setting must match the corresponding parity setting in the host

computer.

Data Terminal Ready

This configuration is part of hardware flow control and determines when the Data

Terminal Ready (DTR) signal is generated. This signal indicates whether or not

the printer is ready to receive data.

True continuously asserts the DTR signal.

False never asserts the DTR signal.

On–Line and BNF (buffer not full) asserts the DTR signal when the

printer is online and the internal serial buffer is not full.

Off–Line or BF (buffer full) asserts the DTR signal when the printer is

offline or the internal serial buffer is full.

On–Line asserts the DTR signal when the printer is online.

Advertising