Printronix Series 5 User Manual

Page 201

Advertising
background image

6–8

Troubleshooting

Table 6–1 LCD Message Troubleshooting Table (continued)

Displayed Message

Can

User

Correct?

Explanation

Solution

HB NOT INSTALLD*

No

Self–test does not detect
hammer coils.

Contact your authorized service
representative.

1

06 HOST REQUEST

Yes

Host attention message.

The host computer or printer
controller requires attention.

ILL EXT BUS ACC*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

ILLGL OPR ACCSS*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

ILL INST ACCSS*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

INTAKE FAN FAULT

Yes

Sensors cannot detect
current in fan circuit.

See description for
HMR BANK FAN FLT.

INVALID ACTIVATE

No

Printer detects twinax
protocol communication
errors.

The printer reports the error.

22 INVALID ADDR

Yes

Unit address not
recognized by printer.
(Twinax interface)

Ensure that printer address
matches host setting.

INVALID COMMAND

No

Printer detects twinax
protocol communication
errors.

The printer reports the error, host
action is required.

LO DRV. SHORT *

No

Circuit(s) on the hammer
bank or in the hammer
bank power cable shorted
to ground.

Contact your authorized service
representative.

1

LOAD PAPER

Yes

Printer is out of paper.

Load paper.

ONLINE

CU TIMED OUT

Yes

Enable poll timeout, The
printer was not enabled for
one minute. (Coax
interface)

Check cable connection and host
system.

ONLINE

28 CU NOT ENAB

Yes

Poll timeout error. The
printer was not polled for
one minute. (Coax
interface)

Check cable connection and host
system.

ONLINE

8344 FAILED

No

Link–level code test
detects hardware failure.

Contact your authorized service
representative.

1

PAP BAD TABLE*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

UNDFNED OPCODE*

No

Fatal firmware error on
controller board.

Contact your authorized service
representative.

1

Advertising