Configuration Menus

Ignore ch#1

Specifies character 1 for the character filtering option. Valid values for

n

are from

0 through 255.

Ignore ch#2

Specifies character 2 for the character filtering option. Valid values for

n

are from

0 through 255.

Data Bit 8

When data bit 8 is enabled, the PI line is not passed directly from host to printer;

all 8 bits are used for data bits, and characters in the 80–FF hex range can be

accessed.

When data bit 8 is disabled (and the host PI line is enabled), data bit 8 internally

indicates PI line status. To use the PI line, disable data bit 8, and enable the Host

PI configuration option (under the PI Control option on

page 4–37

).

NOTE: Data bit 8 is interpreted as

either

data bit 8 or PI signal, but never

both. When enabled as data bit 8, data bit 8 has priority over the PI

signal, and all data above 7F hex is used to access character data

and not to interpret PI line data.

Conversely, when data bit 8 is disabled and the PI signal is used, data bit 8 of the

data is reserved for use as the PI function, and you cannot access characters in

the 80–FF hex range. Therefore, to access characters in the 80–FF hex range,

data bit 8

must

be enabled.

Font Set

The Font Set specifies which language is currently selected for use with the VGL.

Refer to

page 4–38

for available selections.