5–15

Interfaces

RS–232 and RS–422 Serial Interfaces

NOTE: The RS–232 and RS–422 serial interface circuit characteristics are

compatible with the Electronic Industry Association Specifications

EIA–232–E and EIA–422–B.

The RS–232 and RS–422 serial interfaces enable the printer to operate with bit

serial devices that are compatible with an RS–232 controller. The input serial

data transfer rate (in baud) is selectable from the printer’s control panel. Baud

rates of 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115K baud

rates are available.

NOTE: If you select a baud rate that is greater than 19200, you may need

to use RS–422 to prevent data loss. You may also need to increase

the Buffer Size in K parameter from the default (1 Kbyte), to

improve performance.

The length of the data cable from the host computer to the printer must not

exceed 50 feet (15 meters) for RS–232 or 4000 feet (1220 meters) for RS–422.

(A copper conductor, twisted–pair telephone cable with a shunt capacitance of 16

pF/foot (52.5 pF/meter) terminated in a 100 ohm resistive load must be used for

the RS–422.)