Input signal and pin no. of connector cn x5, Input signals (common) and their functions – Panasonic MINAS E-series User Manual

Page 107

Advertising
background image

107

[Connections and Settings in Internal Velocity Control Mode]

Connections and

Settings in Internal

V

e

locity Control Mode

Signal Name

Control Signal Power

Supply Input (+)

Control Signal Power

Supply Input (—)

Servo-ON input

Alarm Clear Input

Deviation Counter

Clear/Internal

Command Speed

Selection 2 Input

• Connect positive (+) pole of external DC power supply (12 to

24V).

• Total supply voltage should range from 12V

± 5% to 24V ± 5%.

• Connect negative (-) pole of external DC power supply (12 to

24V).

• The voltage source capacity varies depending on configuration

of input/output circuits to be used. We recommend 0.5A or

greater.

• When this signal is connected to COM-, the driver will be

enabled (Servo-ON) (motor energized).

• If this signal is connected to COM- for 120 ms or longer, it will

clear alarm status.

• There are some alarms that this signal cannot release.

For details, refer to “Protective Functions” on Page 144 of

Edition of When You Have Trouble.

The control mode changes functions.

1

13

2

3

4

——

SI

Page 106

SI

Page 106

SI

Page 106

Pin No.

Symbol

Function

I/F Circuit

Input Signal and Pin No. of Connector CN X5

Input signals (common) and their functions

COM+

COM–

SRV-ON

A-CLR

CL/

INTSPD2

<Cautions>

1. The signal will become valid about 2 seconds after power-ON.

(See the timing chart.)

2. Don’t use Servo ON/OFF signal to drive/stop the motor. Refer to “Dynamic Brake”

on Page 36 of Preparation edition.

Take the time of 100 ms or longer before entering a command on speed, pulse, etc.,

after transition to Servo-ON.

When you open the connection with COM-, the driver will be disabled (Servo-OFF)

and the current flow to the motor will be cut off.

You can select dynamic brake operation during Servo-OFF and clear operation of

the deviation counter by using Pr69 (sequence during Servo-OFF).

Position

Control

Internal

Velocity

Control

• Input of this signal is to clear the deviation counter.

• When the signal is connected to COM- for 2 ms or longer, it will

clear the deviation counter.

• With input of internal command speed selection 2 (INTSPD2),

four-speed can be set in combination with INTSPD1 input.

• For details on settings of control mode, refer to Page 117.