[Connections and Settings in Internal Velocity Control Mode]

Connections and

Settings in Internal

V

e

locity Control Mode

SO1

Page 106

SO1

Page 106

SO1

Page 106

SO1

Page 106

PO1

Page 106

PO2

Page 106

I/F Circuit

Signal Name

Servo Alarm Output

Positioning
Completion/
Achieved Speed
Output

Brake Release Signal
Output

Warning Output

Phase-A Output

Phase-B Output

Phase-Z Output

Phase-Z Output

• The output transistor turns OFF when an alarm is generated.

• The control mode changes functions.

• This signal is used to release the electromagnetic brake of the

motor.

• The output transistor turns ON when the brake is released.
• Refer to “Timing Chart” on Page 32 of Preparation edition.
• A signal selected with Pr09 (warning output selection) is output.

• This signal provides differential output of the encoder signal

(Phases A/B/Z) that undergoes dividing process (RS 422
phase, etc.).

• The logical relation between phases A and B can be selected

with Pr45 (Pulse output logic inversion).

• Not insulated
• Phase Z signal output in an open collector
• Not insulated

9

10

11

12

15
16
17
18
19
20
19

ALM

COIN

BRK-OFF

WARN

OA+
OA–
OB+
OB–
OZ+

OZ–

CZ

Pin No.

Symbol

Function

Output Signals (Others) and their Functions

Signal Name

Signal Ground

Frame Ground

• Signal ground in the driver
• Insulated from the control signal power supply (COM-) in the

driver.

• Connected with the earth terminal in the driver.

14

26

GND

FG

––

––

Pin No.

Symbol

Function

I/F Circuit

Output Signal and Pin No. of Connector CN X5

Output Signals (Common) and their Functions

Functions
The output transistor turns ON while torque is limited.
The output transistor turns ON when the speed falls below setting of Pr61
(zero speed).
The output transistor turns ON when any of the following 3 warning
functions is activated: regenerative/overload/fan rotation speed
abnormality.
With the regenerative warning function activated (85% of the
regenerative abnormality detection level is exceeded), the output
transistor turns ON.
With overload warning function activated (effective torque exceeds
85% when the detection level of overload protection is considered
100%), the output transistor turns ON.
Displays may appear but do not function.
With the abnormal fan rotation speed warning function activated (the
fan stops), the output transistor turns ON.

Settings

0
1

2

*

[default value]

3

*

4

*

5

*

6

*

With settings of 2 to 6, once a warning is detected, the output transistor turns ON for
at least 1 second.

Position
Control

Internal
Velocity
Control

• Positioning completion output
• The output transistor turns ON when the deviation pulse does

not exceed setting of Pr60 (In-position range).

• Achieved Speed Output
• The output transistor turns ON when motor speed exceeds Pr62

(At-speed).