Maintenance/Inspection

• Routine maintenance and inspections are essential for proper and satisfactory operation of the driver

and motor.

Notes to Maintenance/Inspections Personnel

(1) Power-on/off operations should be done by the operators themselves.

(2) For a while after power off, the internal circuits is kept charged at higher voltage. Inspections should be done a

while (about 10 minutes), after the power is turned off and the LED lamp on the panel is extinguished.

(3) When conducting meager test (to measure insulation resistance) on the servo driver, disconnect all the connec-

tions from the driver. Conducting the test as connected would cause trouble of the driver.

Inspection Items and Cycles

Normal (correct) operating conditions:

Ambient temperature: 30˚C (annual average) Load factor: max. 80%

Operating hours: max. 20 hours per day

Daily and periodical inspections should be done per the following instructions.

<Notes>

If the operating conditions (as stated above) differ, this periodic inspection interval is subject to change.

Type

Daily inspection

Periodical

inspection

Cycles

Daily

Every year

Inspection items

• Ambient temperature, humidity, dust, particles, foreign matters, etc.

• Abnormal sound and vibration

• Main circuit voltage

• Odor

• No yarn piece, etc. adhered to the air hole?

• How the driver front and connector are cleaned?

• Each wired cable is damage-free?

• The portions connected with the motors of equipment/plant are free

from loose and center deviation?

• No inclusion of foreign matter at the load side?

• Loosened screws

• Signs of overheat

We make the utmost effort to ensure the quality of our product. However, the product may

operate differently from your settings, due to unexpectedly high exogenous noise/applied

static electricity, or an unforeseen failure in the input power supply, wiring, components, etc.

Hence, we would like to request you to give adequate consideration to the fail-safe design and

assurance of safety within the operable range at the place of operation in your company.