Example of connection to a host controller, Connections and settings in position control mode, Matsushita electric works, ltd. fpg-c32t – Panasonic MINAS E-series User Manual

Page 73: This represents a twisted pair cable. <remarks

Advertising
background image

73

[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

2k

2k

5.6k

3k

5.6k

5.6k

220

220

4.7k

4.7k

4.7k

4.7k

4.7k

4.7k

CW pulse command
output

CCW pulse command
output

CW pulse
command
input

Y0

Y1

X2

COM

+

Y2

COM

X3

X5

X6

PULS1

PULS2

SIGN1

SIGN2

CZ

GND

COM+

CL

SRV-ON

GAIN/TC

A-CLR

CCWL

CWL

ALM

COIN

BRKOFF

WARN

COM–

22

23

24

25

21

14

1

4

2

5

3

8

7

9

10

11

12

13

CCW pulse
command
input

Origin input

Deviation counter
reset output

Counter
clear input

Servo-ON
input

Servo alarm
output

Positioning
completion output

Brake release
output

Alarm clear
input

CW overtravel
inhibit input

CCW overtravel
inhibit input

PLC

FPG-C32T (Matsushita Electric Works, Ltd. FP

∑)

Driver

E-series

Phase Z
output

Origin proximity
sensor

CW limit sensor

CCW limit sensor

From PLC
I/O output

To PLC
I/O input

GND +24V

DC24V

power supply

Origin proximity input

CCW limit over input

CW limit over input

Warning output

Gain switching
input/torque limit
switching input

Example of Connection to a Host Controller

Matsushita Electric Works, Ltd. FPG-C32T

This represents a twisted pair cable.

<Remarks>