Wiring to Connector CN X5

Signal Name

Gain Switching/

Speed Zero Clamp/

Torque Limit

Switching Input

Command Dividing

Multiplier Switching/

Internal Command

Speed Selection 1

Input

CW Overtravel

Inhibit Input

CCW Overtravel

Inhibit Input

• Settings of Pr06 and control mode can change functions.

The control mode can change functions.

• If you open connection with COM- when a moving part of the

machine exceeds the movable range in CW direction, no

torque will be generated in CW direction.

• If you open connection with COM- when a moving part of the

machine exceeds the movable range in CCW direction, no

torque will be generated in CCW direction.

• If you set 1 to Pr04 (Invalid Overtravel Inhibit Input), CWL/

CCWL inputs will be invalid. A default value is invalid (1).

• Setting of Pr66 (DB inaction during driving prohibition) can activate

the dynamic brake when CWL/CCWL input is valid. According to a

default value, the dynamic brake will run (Pr66 is 0).

5

6

7

8

GAIN

/ZEROSPD

/TC

DIV

/INTSPD1

CWL

CCWL

SI

Page 106

SI

Page 106

SI

Page 106

SI

Page 106

Pin No.

Symbol

Function

I/F Circuit

Pr06

0, 1

2

For details on the 2nd gain switching function, refer to Page 138.

Content

Control Mode

Connection with COM-

Open

1st setting value selected. (Pr70,5E,63)

Connected

2nd setting value selected. (Pr71,72,73)

Pr06

0

ZEROSPD input is invalid.

1 [default value]

ZEROSPD input is valid.

Setting of Pr30

Content

0

[default value]

Velocity loop: P1 (proportional/integral) operation

Setting of Pr31

Connection

with COM-

Open

Connected

Velocity loop: P (proportion) operation

1st gain selected (Pr10,11,12,13,14)

1

Open

Connected

2

2nd gain selected (Pr18,19,1A,1B,1C)

When

position

control

Pr02 is

0 or 2

When

internal
velocity

control

Pr02 is 1

The following 2 functions can be used with settings of Pr30.
Gain switching input (GAIN) switches P1/P operation and

first/second gain.

With speed zero clamp input (ZEROSPD), velocity command is

opened when connection with COM- is opened.

You can override this input with Pr06.
A default value of Pr06 is 1, and this input is valid. When

connection with COM- is opened, speed will be zero.

Content

Content

Position
Control/

Internal

Velocity

Control

With torque limit switching input, parameters of acceleration level,
torque limit, excessive position deviation can be switched.

• Input to switch dividing multiply of command pulse

• When this signal is connected to COM-, it will switch a command

dividing multiply numerator from Pr46 (Numerator of 1st command

pulse ratio) to Pr47 (Numerator of 2nd command pulse ratio).

<Caution>

You must not enter any command pulse for 10 ms before or after

switching.

• With internal command speed selection 1 (INTSPD1), four-speed

can be set in combination with INTSPD 2.

• For details on settings of control mode, refer to Page 117.

Position

Control

Internal

Velocity

Control