Specifications (driver/motor), Specifications – Panasonic MINAS E-series User Manual

Page 206

Advertising
background image

206

Power
Supply

Control method

Detector

Built-in
functions

Protective
Function

Monitor
Setting

Position
Control

Velocity
Control

Rotary
Encoder
Control Input

Structure

Mass

Ambient Conditions

Rated Rotation Speed

Maximum Rotation Speed

Holding Brake

Rotary Encoder

Structure (dust-proof/drip-proof protection)

Mass

Ambient Conditions

Single-phase 100V

Allowable frequency variations

Specification of applicable rotary encoder

Regeneration

Dynamic brake

Auto gain tuning

Electronic gear

(Dividing/multiplier of a command pulse)

Dividing of feedback pulse

Panel Display

Communications

Maximum Input Pulse Frequency

Form

Type

Internal command speed

Acceleration time setting
Rotary encoder
feedback signal

Phases Z

100V

200V

Within –5%

IGBT transistor PWM control (Sine wave driving)

Incremental encoder 5-wire 2500 P/r

Externally installed regenerative resistor

At power-off, Servo-OFF, activation of protective function, and activation
of limit switches

Normal, real time

A value resulting from the calculation of

Status LED (STATUS), alarm code LED (ALM CODE)

RS232C

Line driver 500 kpps, open collector 200 kpps

Line driver, open collector

90ß phase difference two-phase pulse, CW/CCW pulse, pulse row + sign

0 to 10 s/1000r/min, possible to individually set acceleration/
deceleration.

Line driver output

Line driver output, Open collector output

Refer to Section "System Configuration and Wiring".

Base mount type, open (IPOO)

Refer to Section "Dimensional Outline Drawing of Driver".

Refer to Section "Installation".

3000r/min

50W - 200W: 5000r/min

50W - 400W: 5000r/min

Refer to Section "Holding Brake Built in the Servo Motor" for DC24V.

Incremental encoder 5-wire 2500 P/r

Equivalent to IP65 (excluding connector unit, shaft-through part)

Refer to Section "Dimensional Outline Drawing".

Refer to Section "Installation".

Driver

Four-speed setup (Capable of setting CW/CCW, up to
20000r/min. However, use it within the use range of the motor.)

Single-phase 200V

Three-phase 200V

Single-phase AC100V

Single-phase AC200V

Two-phase pulse of 5 to 2500 P/r output at any number of pulse

Capable of storing 14 alarms
including a current alarm code
No.
Note, however, that alarm
marked with * cannot be stored.

Undervoltage*, overvoltage, overcurrent, overload,
regenerative overload, encoder error, position over-deviation,
over-speed, command pulse dividing error, position deviation
overflow, EEPROM data error* (abnormal parameter,
abnormal check code), overtravel input error*, etc.

Phases A

B

1 - 10000

1 - 10000

2

0 - 17

Three-phase AC200V

+10%
—15%

- 115V

+10%
—15%

50/60Hz

+10%
—15%

- 240V

+10%
—15%

50/60Hz

+10%
—15%

- 240V

+10%
—15%

50/60Hz

Motor

Specifications

Advertising