Timing chart – Panasonic MINAS E-series User Manual

Page 32

Advertising
background image

32

Timing Chart

Power Supply

Internal Control
Power Supply

Initialization of
Driver

Servo-ON Input
(SRV-ON)
(X5 2 pins)

Dynamic Brake

Motor Energized

Brake Release
Output
(BRK-OFF)
(X5 11 pins)

Position/Velocity
Command

ON

ON

Normal Operation

OFF

* 1

OFF (Braking Operation)

ON

(Brake Release)

OFF

ON

Not Energized

Energized

Not input

Input

100ms or Longer

Approx.
700 ms

Established

Initialize Approx. 2 seconds

Approx. 40 ms

Approx. 1 - 5 ms

Approx. 10 ms

Approx. 2 seconds

OFF

-

After Power-ON (Receiving Servo-ON Signal)

<Cautions>

• The above chart shows timing from AC power-ON to command input.

• Enter Servo-ON signal and external command according to the above timing chart.

*1: During this period, the SRV-ON signal has not been accepted although it was mechanically input.