56

Using the Console

Auto recognition is active (always indicated as shown on the left).

Load factor is indicated as a percentage with reference to the rated load 100%.

Total number of the pulses after
turning on the control power.
This display overflows as shown
on the right.

CW direction

CCW direction

Turning on the

control power −32768 pulses

32767 pulses

0

−32768 pulses

The indicated total pulse number can be reset (comes to 0) by pressing about 5 seconds or more.

SET

S

Auto recognition of motor

Warning display

Display of regenerative load factor

Display of overload factor

Warning of overload: Load has exceeded 85% of the level where overload

protection alarm occurs.

Warning of regenerative overload:
Regenerative load has exceeded 85% of the level where regenerative overload protection
alarm occurs. When externally added regenerative resistor, Parameter No. 6C, is selected
to be "1", the alarm is set to occur at 10% of the full working level of the regenerative resistor.

For manufacturer use : Can not be used.

No occurrence of warning

Occurrence of warning

Regenerative resistor load factor is indicated as a percentage with
reference to 100% level where regenerative protection is activated.

Display of inertia ratio

Display of total number of feedback pulses and total number of control pulses

Inertia ratio is indicated in percent.

•••Can not be used.

With externally added resistor, this display is active when parameter Pr6C is set to “0” or “1”.

See also “Overload Protection Time-limiting Characteristics” on Page 146.

•••Can not be used.