Trouble case – Panasonic MINAS E-series User Manual

Page 151

Advertising
background image

151

[Trouble Case]

T

rouble Case

The rotation is not stable (the rotation is not smooth)

Category

Adjustment

Wiring

Cause

Poor gain adjustment

Position command (pulse row

command) is unstable.

The following input signals of CN X5

are chattering.

(1) Servo-ON signal

(2) Deviation counter input signal

(3) Zero speed clamp signal

(4) Internal command speed selection 1

and 2 input signals

Action

Increase the value of the 1st velocity loop gain Pr11. Insert a

1st torque filter Pr14 and increase the value of Pr11 again.

Check how the motor is running, by using the waveform graphic

function of PANATERM

®

. Check the wiring and connectors for

poor contact. Also check the controller.

(1) Using the I/O signal status display function, check wiring

and connection between the connector CN X5 pins 2 and

13. Modify the wiring and connection so that Servo-ON

signal successfully turns ON. Check the controller.

(2) Using the I/O signal status display function, check wiring

and connection between the connector CN X5 pins 4 and

13. Modify the wiring and connection so that the deviation

counter input successfully turns ON. Check the controller.

(3) Using the I/O signal status display function, check wiring

and connection between the connector CN X5 pins 5 and

13. Modify the wiring and connection so that the zero speed

clamp input successfully turns ON. Check the controller.

(4) Using the I/O signal status display function, check wiring

and connection between the connector CN X5 pins 4 and

13, and 6 and 13. Modify the wiring and connection so that

the internal command speed selection 1/2 input successfully

turn ON. Check the controller.