System configuration and wiring, Wiring diagrams – Panasonic MINAS E-series User Manual
Page 28

28
System Configuration and Wiring
Wiring Diagrams
Compose such a power supply as to switch OFF the power against alarm output.
For three-phase 200V
Noise
filter
Red
(Tyco Electronics
AMP K.K.)
Power supply
(Tyco Electronics
AMP K.K.)
White or
yellow
Green
yellow
Motor
172167-1
(Molex Incorporated)
5557-10R-210
(Molex Incorporated)
5557-06R-210
172159-1
1
2
ALM
V
DC
9
3
6
4
1
3
5
6
8
10
ALM
L2
L3
P
P
P
MC
L
MC
NFB
MC
ON
OFF
ALM
N
N
B
U
V
E
W
L1
COM —
13
12~24V
3
4
Black
CN X1
CN X3
CN X5
Noise
filter
Red
(Tyco Electronics
AMP K.K.)
Power supply
(Tyco Electronics
AMP K.K.)
White or
yellow
Green
yellow
Motor
172167-1
(Molex Incorporated)
5557-10R-210
(Molex Incorporated)
5557-06R-210
172159-1
1
2
ALM
V
DC
9
3
6
4
1
3
5
6
10
ALM
L2
L3
P
P
P
MC
L
MC
NFB
MC
ON
OFF
N
N
B
U
V
E
W
L1
COM —
13
12~24V
3
4
Black
ALM
CN X1
CN X3
CN X5
For single-phase 200V,
use the reactor for
three-phase.
For Single-phase 100V/200V