Test run in position control mode, Inspection prior to test run, Test run with connector cn x5 connected – Panasonic MINAS E-series User Manual

Page 82: Wiring diagram

Advertising
background image

82

COM+

1

2

13

22

23

21

24

25

14

COM-

SRV-ON

PULS1

PULS2

SIGN1

SIGN2

CZ

GND

120

120

CW/CCW
pulse input
In the case the
open collector is
used for input

Output of phase
Z for initialization

DC
12V ~ 24V

DC
5V

Test Run with Connector CN X5 Connected

(1) Connect CN X5.

(2) Connect the control signal (COM+/COM-) to the power

supply (12 to 24 VDC).

(3) Turn on the power (of the driver).

(4) Check default settings of parameters.

(5) Activate Servo-ON by connecting Servo-ON input SRV-

ON (CN X5 pin 2) and COM- (CN X5 pin 13). Then the

motor will be energized.

(6) Set Pr42 (command pulse input mode set up)

according to output form of the host controller, and

write it into EEPROM. Then, you should turn the power

OFF and ON again.

(7) Send a low-frequency pulse signal from the host

controller to run the motor at low speed.

(8) Check rotation speed of the motor in the monitor mode.

• Check that the motor rotates at set speed.

• Check if the motor stops when you stop the command

(pulse).

Wiring Diagram

(1) Check the wirings:

• Connected correctly

(especially power supply

connection and motor

connection),

• Not shorted and properly

earthed, and

• Not loose.

(2) Check the supply

voltage:

• Check that the rated

voltage is supplied.

(3) Install the motor:

• Check that the servo-

motor is firmly installed.

(4) Isolate the mechanical load.

• Perform a test run of the

motor independently.

(5) Release the brake.

x

1

x

3

x

4

x

5

x

6

STATUS

ALM CODE

Host Controller

CN X4

Ground

Power

supply

Motor

Machine

Test Run in Position Control Mode

Inspection prior to Test Run