Preparations, Points in wiring wiring diagram – Panasonic MINAS E-series User Manual

Page 29

Advertising
background image

29

[Preparations]

Preparations

Wiring to Connector CN X4 (Connection with Encoder)

Points in Wiring

Wiring Diagram

¥ When you plan to make an encoder junction cable by yourself, refer to Requests on a self-made encoder junction

cable (For connectors, refer to Optional Parts (Connector Kits for Connection of Motor and Encoder) on Page

186 of Reference edition).

(1) Refer to the wiring diagram below.

(2) Cable used: Shielded twist pair cable of 0.18 mm

2

(AWG 24) minimum in conductor diameter that is excellent in

bending resistance.

(3) For signal/power wiring in pair,

use twist pair cable.

(4) Shielding treatment
Driver-side shield sheath:

Connect to CNX4 connector
case (FG).

Motor-side shield sheath:

Connect to 6 pins.

(5) Where the cable length

exceeds 10 m, do double-
wiring for the encoder power
(+5V, 0V), as illustrated left.

(6) Connect nothing to the empty

terminal (NC) of the
connector.

Servo motor

2

0V

+5V

1

4

5

3

6

Case

5

4

1

2

3

6

Twist pair

Junction cable

(made by Tyco Electronics AMP K.K.)

172160-1

172168-1

(made by Tyco

Electronics AMP K.K.)

Motor side

Servo driver side

White

Light blue

Purple

Shielded
cable

Black

Regulator

0V

+5V

0V

+5V

TX/RX

TX/RX

FG

0V

+5V

(NC)

TX/RX

TX/RX

FG

X4

CN

(7) Don’t use a cable pair composed of the motor cable and encoder cable which were shielded in batch.

Cable length between the driver and the motor - 20 m max.

If this cable length exceeds 20 m, consult with the

dealer/distributor from which you have purchased the

driver.

Keep 30 cm or more spacing from the main circuit wiring.

Neither guide this wiring through the same duct, together

with the main circuit nor bundle these two together.

x

1

x

3

x

4

x

5

x

6

STATUS

ALM CODE

Power

section

Motor

Encoder

30 cm min.

30 cm min.

20 m max.

Advertising