Parameters for torque limits, Parameters for sequences, Standard default setup – Panasonic MINAS E-series User Manual

Page 123

Advertising
background image

123

[Connections and Settings in Internal Velocity Control Mode]

Connections and

Settings in Internal

V

e

locity Control Mode

Parameters for Torque Limits

PrNo.

Parameter Name

Function/Content

• With this parameter set, maximum torque of the motor is limited in the driver.
• Normal specification allows torque about 3 times as large as rated torque, if in an

instant. We recommend that you limit the maximum torque with this parameter if the
tripled torque might cause trouble to intensity of the motor load (machine).

5E

1st torque limit set-

up

0 -

500

• You can give setting as a percentage

(%) value to rated torque.

• The right figure shows an example in

which it is limited to 150%.

• Pr5E limits the maximum torque of

both CW and CCW directions simulta-

neously.

Speed

200

100 (Rated)

(Rated)

100

200

300

Torque [%]

300 (Max.)

(Max.)

CW

CCW

When Pr5E=150

<Remarks>
With torque limit switching function enabled (Pr06=2), this parameter is a
value of the 1st torque limit.
<Cautions>
You cannot set to this parameter a value that exceeds a default setup value with
“Maximum Output Torque Setting” of the system parameter (i.e., factory default
parameters that cannot be changed through manipulation of PANATERM

®

and

console). A default may differ depending on a combination of a motor and driver. For
detailed information, refer to “Setting of 1st Torque Limit” on Page 45 of Preparation
edition.

Parameters for Sequences

Standard Default Setup: [ ]

PrNo.

Parameter Name

Function/Content

• The parameter directly sets in [r/min] timing to output zero speed detection

output signal (WARN: CN X5 pin 12).

You need to set parameter warning output selection (Pr09) to 1.

• The zero speed detection signal (WARN) will be output when the motor speed

falls below the set speed of this parameter Pr61.

• In internal velocity control mode, the parameter sets timing to output achieved

speed signal (COIN: CN X5 pin 10) with rotation speed [r/min].

• The achieved speed signal will be output when the motor speed exceeds the

speed set by this parameter Pr62.

61

62

Zero speed

At-speed

0 -

20000

[50]

0 -

20000

[1000]

• Setting of Pr61 acts on both CW and

CCW directions, irrespective of the

direction of motor rotation.

• There is hysteresis of 10 rpm. Set the

parameter 10 or more.

Speed

CW

WARN

ON

Pr61

Pr61

CCW

• Setting of Pr62 works on both CW and

CCW directions, irrespective of

rotation direction of the motor.

• There is hysteresis of 10 rpm. Set the

parameter 10 or more.

Speed

CW

COIN

OFF

ON

CCW

Pr62

Pr62

Range of

Settings

Range of

Settings

Advertising