Parameters for auto gain tuning, Parameter setting – Panasonic MINAS E-series User Manual

Page 120

Advertising
background image

120

Parameter Setting

PrNo.

Parameter Name

Unit

Function/Content

• The parameter sets a ratio of load inertia to rotor inertia of the motor.

• When you execute auto gain tuning, load inertia is estimated and the

result will be reflected in the parameter.
If inertia ratio has been set correctly, Pr11 and Pr19 will be set in
(Hz). When Pr20 inertia ratio is greater than actual value, setting
unit of the velocity loop gain will be greater. If inertia ratio is smaller
than actual value, setting unit of the velocity loop will be smaller.

• The inertia ratio estimated during execution of real time auto tuning

is saved in EEPROM every 30 minutes.

• The parameter sets an operation mode of real time auto tuning. As

you set this to a higher value such as 3, 6…, inertia change during
operation will be quickly responded. However, operation may
become unstable, depending on the operation pattern. Thus, we
recommend that you usually set the parameter to 1 or 4.

• In internal velocity control mode, the adaptaive filter function is

disalbed, and thus Pr2F adaptive filter frequency will be reset to 0.

• The parameter sets mechanical stiffness during execution of real

time auto tuning in 16 stages.

• If you change a setting sharply and abruptly, gain will vary suddenly,

thus giving impact to the machine. Be sure to start with a small
setting and gradually increase it while observing how the machine is
running.

• The parameter sets operation patterns of normal auto gain tuning.

20

21

22

25

Inertia ratio

Real time auto
tuning set-up

Machine stiffness
at auto turning

Normal auto tuning
motion set-up

0 - 10000

[100]*

0 - 7

0 - 15

[4]

0 - 7

%

Pr20 = (Load inertia/rotor inertia) x 100 [%]

<Remarks>

Parameters having standard default setup value with “*” mark are automatically set while real time auto
gain tuning is running. To change to manual, refer to “Cancellation of the Automatic Gain Tuning” on Page
135 of Adjustment edition, disable real time auto gain tuning and then set.

Parameters for Auto Gain Tuning

Standard Default Setup: [ ]

Range of

Settings

Low

← Mechanical stiffness →High

Low

← Servo gain →

High

Low

← Responsiveness → High

Pr22

0 • 1- - - - - - - - - - - - 14 • 15

Settings

[0]

1

2

3

4

5

6

7

Number of Rotations

2 rotations

1 rotation

Rotation Direction

CCW

→ CW

CW

→ CCW

CCW

→ CCW

CW

→ CW

CCW

→ CW

CW

→ CCW

CCW

→ CCW

CW

→ CW

• Any change to this parameter will be valid when Servo-OFF switches to Servo-ON.
<Remarks> For Pr02=1 (in internal velocity control mode), you can set the parameter only when the first notch
filter is set as disabled.

Settings

0

[1]

2

3

4

5

6

7

Real time auto tuning

Not used

Used

Not used

Degree of changes in load inertia during operation

Little change

Gradual change

Sharp change

Little change

Gradual change

Sharp change

Adaptive filter

No

Advertising