Timing chart – Panasonic MINAS E-series User Manual

Page 34

Advertising
background image

34

Timing Chart

OFF

OFF

ON

Operation

Release

Not Energized

Operation *3

* 4

Not Energized

Energized

Operation

(OFF)

Operation

(OFF)

Operation

(OFF)

Release

(ON)

Release

(ON)

Servo-ON input will not be active
until the motor rotation speed
falls below approx. 30r/min.

Approx. 1 - 5 ms

Approx.

40 ms

Setting of Pr.6B

When the time defined by
Pr.6B is reached earlier.

Setting of Pr.6B

Approx. 10 ms

Approx. 30 r/min

Dynamic Brake

Motor Energized

Motor Rotation
Speed

Number of Motor Rotations

Servo enabled

Brake Release
Output
(BRK-OFF)

Servo-ON Input
(SRV-ON)

When the motor rotation speed
falls below 30r/min earlier.

Motor Rotation Speed A

Approx. 30 r/min

Motor Rotation Speed B

Approx. 30 r/min

t1 * 1

t1 * 1

Servo-ON/OFF Operation When the Motor is Rotating

(The following chart shows timing in the case of emergency stop or trip. You cannot use Servo-ON/OFF

repeatedly.)

<Cautions>

*1. A value of t1 is a value of Pr6B or time needed for decreasing motor speed to approx. 30 r/min,

whichever is shorter.

*2. Even if SRV-ON signal turns on again during deceleration of the motor, SRV-ON input does not become

active until it stops.

*3. For operation of the dynamic brake during Servo-OFF, also refer to the description of “Sequence at

Servo-OFF” (“Parameter Settings” of every control mode) on Pr69.

*4. Servo-ON input will not be active until the motor rotation speed falls below approx. 30r/min.

Servo-ON/OFF Operation When the Motor is Stopped

(During normal operation, perform the Servo-ON/OFF operation after the motor stops.)

<Cautions>

*1. A value of t1 depends on a setting of Pr6A.

*2. For the operation of the dynamic brake during Servo-OFF, also refer to the description of “Sequence

during Servo-OFF” (“Parameter Settings” of every control mode) on Pr69.

*3. Servo-ON input will not be active until the motor rotation speed falls below approx. 30r/min.

Dynamic Brake

Motor Energized

Brake Release
Output (BRK-OFF)

Servo-ON Input
(SRV-ON)

Approx. 40 ms

Approx. 1 - 5 ms

Approx. 10 ms

Approx. 1 - 5 ms

t1 *1

Release (ON)

OFF

Not Energized

ON

Release

Energized

Operation (OFF)

OFF

Operation *2

Operation *3

Not Energized

Operation (OFF)

When you turn off the power of the electromagnetic brake, the motor brake will run. When you turn on the
power of the electromagnetic brake, the motor brake will be released.