Homing operation (precautions), Example of homing operation – Panasonic MINAS E-series User Manual

Page 38

Advertising
background image

38

Homing Operation (Precautions)

In initialization (i.e., operation to return to a home position) by using the host controller, if origin input (Z-phase

from the encoder) is entered before the motor has not adequately decelerated since the proximity sensor was

activated, the motor may not stop at a requested position. In order to prevent this, determine positions where the

proximity input and origin input turn on, by taking into consideration the number of pulses required for successful

deceleration. As settings of parameters “acceleration/deceleration time” have also effects on initialization,

consider both positioning and initialization when you set them.

For detailed information on initialization, refer to the operating manual for the host controller.

Example of Homing Operation

Proximity dog on .... When the proximity input turns ON, the motor will start to decelerate, and stop when a first

origin input (Z phase) is entered.

Proximity dog off .... When the proximity input turns ON, the motor will start to decelerate, and stop when a first

origin input (Z phase) is entered after the proximity input turns off.

Proximity Input

Origin Input

Proximity Sensor Dog

Z-phase output from encoder

Speed

Proximity Input

Origin Input

Proximity Sensor Dog

Z-phase output from encoder

Speed

Advertising