Zhone Technologies IMACS-200 User Manual

Page 167

Advertising
background image

E&M Ports

7-7

Table 7-1. Main Screen Actions

Table 7-2, “Main Screen Option Settings and Defaults,” on page 7-7 summarizes the
configuration settings for the E&M port, along with the available and factory-default option
settings. The parameters and settings are also described in the following paragraphs.

Table 7-2. Main Screen Option Settings and Defaults

Notes:

1. The extended setting range for the IMACS-200 E&M port is from -16.3 to +7.5 dB.

2. When a WAN or SRV port has not been selected, or when the mode it to, the default
for Signal Conversion is n/a. When the mode has been selected to be e&m, then the
default is off.

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e., test status).

Copy

Copies the contents of the current column to the next column. Useful if you
change a lot of entries in one column and wants to repeat those changes in
subsequent columns.

Test

Access is given to the test screen

taBs

Index into the signaling conversion screen.

Main

Returns to the System Main Screen. If you make changes to settings and do
not save them, you will be prompted to save or lose changes.

Parameter

User Options

Notes

Default

STATE

stdby actv

stdby

WAN/SRV

none wan-1 wan-2 wan-3 wan-4 owan-1 owan-2
owan-3 owan-4

none

TS

01-24 or 01-31

01

MODE

to e&m I e&m II e&m IV e&m V

to

Rx TLP

-16.3 dB to +7.5 dB

0

Tx TLP

-16.3 dB to +7.5 dB

1

0

CODING

u-law a-inv

u-law

LB

off dgtl anlg

off

PATTRN

none D-mW

none

SIG CONV

n/a off on

23

off