2 e&m, fxs and alarm input connector, E&m, fxs and alarm input connector -8, Pair female amphenol connector -8 – Zhone Technologies IMACS-200 User Manual

Page 34

Advertising
background image

2-8

System Installation

Model No.

Running Head

Connector Pin-outs

System Installation

Note:

For purposes of connection and function, the IMACS-200 should be considered a DCE.

2.4.2

E&M, FXS and Alarm input connector

Table 2-5 lists the connector pinouts for the E&M circuits, FXS circuit and the provided alarm input
points. For E&M, “R”, “T” and “M” are consider input direction, “R1”, “T1” and “E” are considered
output direction, and “SB” and “SG” are considered direction-neutral.

23

External Transmit Clock A

24

Terminal Timing A

Not Used

U

25

Test Mode

DCE

NN

Table 2-5. 25-pair female amphenol connector

Port

Designation

Pin

Port

Designation

Pin

E&M
Port 1

T-1

26

E&M
Port 4

T-4

38

E&M
Port1

R-1

1

E&M
Port4

R-4

13

E&M
Port 1

T1-1

27

E&M
Port 4

T1-4

39

E&M
Port 1

R1-1

2

E&M
Port 4

R1-4

14

E&M
Port 1

E-1

28

E&M
Port 4

E-4

40

E&M
Port 1

M-1

3

E&M
Port 4

M-4

15

E&M
Port 1

SG-1

29

E&M
Port 4

SG-4

41

E&M
Port 1

SB-1

4

E&M
Port 4

SB-4

16

E&M
Port 2

T-2

30

FXS
Port 1

T-1

42

E&M
Port 2

R-2

5

FXS
Port 1

R-1

17

Table 2-4. V.35 DB25 female connector

Pin

Signal

Source

V.35 (with PRM-1261F cable)

Advertising