2 test screen – Zhone Technologies IMACS-200 User Manual

Page 171

Advertising
background image

E&M Ports

7-11

7.3.2

Test Screen

The Test option facilitates testing and maintenance by allowing you to monitor and set the
status of the analog interface leads, and to monitor or set the value of the A, B, C, and D
signaling bits of all E&M circuits on that port. In cross-connect systems, the test option also
allows you to apply test patterns and tones towards the user and network sides of the system.

Figure 7-8 shows the E&M port Test Screen parameters,Table 7-3 lists some actions you can
perform from this screen, and Table 7-4 shows the settings for each parameter.

Figure 7-8. Typical E&M port Test Screen

Note:

The above screen shows the ABCD bits as sent by the Tx and Rx sides. The “c”
indicated on ports 3 and 4 indicate that the bits displayed will then be run through the
TABS conversion table as seen in
Table 7-3.

Table 7-3. Test Screen Actions

Table 7-4. Test Screen Option Settings and Defaults

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e. performance and test data).

Main

Returns to the E&M port Main Screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

TEST

off on

off

Tx ABCD

mon set

mon

Advertising