Zhone Technologies IMACS-200 User Manual

Page 173

Advertising
background image

E&M Ports

7-13

TO USER

In cross-connect systems only, the To User parameter allows you to break the circuit and send
a test tone on the user side of the system. The options for this field are none, and D-mW.
Choose none if you do not want to inject a tone toward the CPE. In this case, the PCM signal
received from the network is still sent to the CPE in the normal manner.

TO NTWK

In cross-connect systems only, the To Network parameter allows you to break the circuit and
send a test tone on the network side of the system. The options for this field are none, and
D-mW. Choose none if you do not want to inject a tone toward the network. In this case, the
PCM signal received from the CPE is still sent to the network in the normal manner.

Tx ABCD

The Transmit ABCD informational field shows the current values of the ABCD bits that are
being transmitted to the network. If TX ABCD in the top half of the screen is changed via the
set function mentioned above, and the settings are saved by the Save command in the Menu
of Actions, the new bit pattern chosen will be reflected here.

Rx ABCD

The Receive ABCD informational field shows the current values of the ABCD signaling bits
that are received from the network. If RX ABCD in the top half of the screen is changed via
the set function mentioned above, and the settings are saved by the Save command in the
Menu of Actions, the new bit pattern chosen will be reflected here.

E-lead

The

E-lead information field is a display-only field that reflects the status of the E-lead.

Valid values are on and off.

M-lead

The

M-lead information field is a display-only field that reflects the status of the

M-lead. Valid values are on and off.

MODE

The Mode informational field shows the current mode of the port that was selected on the main
E&M port Screen. Valid settings are E&M.

Advertising