Model no. running head – Zhone Technologies IMACS-200 User Manual

Page 172

Advertising
background image

7-12

E&M Ports

Model No.

Running Head

TEST

The Test parameter shows if the port is in test mode or not. Inactive ports and ports that are
assigned to inactive WANs will show a test status of n/a. The test status options for active
ports are off and on.

Tx ABCD

The Transmit ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being transmitted towards the network or set a specific ABCD pattern for testing the
transmit side of the circuit. The options for this field are mon (monitor) or set. Choosing set
will bring up a four digit field for users to input the ABCD pattern they want to transmit. Any
four-digit combination of ones and zeros is acceptable for this setting.

Rx ABCD

The Receive ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being received from the network or set a specific ABCD pattern for testing the receive
side of the circuit. The options for this field are mon (monitor) or set. Choosing set will bring
up a four digit field for users to input the ABCD pattern they want to receive. Any four digit
combination of ones and zeros is acceptable.

E-lead

The E-lead setting allows the user to either monitor or set the state of the E-lead. The options
for this field are mon (monitor) or set. Choosing set will bring up the options on (which raises
the E-lead), or off (which drops the E-lead.

Rx ABCD

mon set

mon

E-Lead

mon

mon

TO USER

none D-mW

none

TO NTWK

none D-mW

none

Tx ABCD

Status information only; not editable

n/a

Rx ABCD

Status information only; not editable

n/a

E-lead

Status information only; not editable

M-lead

Status information only; not editable

MODE

Status information only; not editable

n/a

TYPE

Status information only; not editable

n/a

STATUS

Status information only; not editable

n/a