8-9

SRU Ports

Test Screen

Table 8-4. Test Screen Actions

Table 8-5. Test Screen Option Settings and Defaults

BERT

Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) on the
selected SRU port. The patterns that can be selected are off, mark (all ones), space (all zeros),
1:1 (alternating 10101010), 1:7 (10000000), 511 (511 test pattern), and 2047 (2047 test
pattern).

DIR

The Direction (DIR) setting allows you to specify where the BERT test signal should be
directed. The first option is net (network) which means that the test signal will be transmitted
through the system toward the Wide Area Network (WAN). The user option means that the
signal will be directed toward the attached DTE device over the RS-232 interface.

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e., test status).

InsertErr

Allows you to manually insert a single error into the clear data signal.

Clear

Clears the Test Screen and resets all counters to zero.

Main

Returns to the SRU port Main Screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

BERT

off mark space 1:1 1:7 511 qrss 2047

off

DIR

net user

net

CTS

norm off on

norm

RLSD

norm off on

norm

SYNC

information only–no user options

*****

BE

information only–no user options

*****

ES

information only–no user options

*****

SES

information only–no user options

*****

CSES

information only–no user options

*****

OSS

information only–no user options

*****

BER

information only–no user options

*****

ELAP

information only–no user options

*****

RTS

information only–no user options

*****

SR OSS

information only–no user options

*****

LB ST

information only–no user options

*****