2 alarm port user screens and settings, 1 alarm filter screen sensor setting, 2 alarm ports main screen – Zhone Technologies IMACS-200 User Manual

Page 210

Advertising
background image

11-2

Alarm Ports

Model No.

Running Head

Alarm port User Screens and Settings

Alarm ports

11.2

Alarm port User Screens and Settings

11.2.1 Alarm Filter Screen Sensor Setting

First, make sure the master setting for all alarm sensors is set properly as the SENSOR variable
in the Alarm Filter Screen. To set this variable, first select Alarms from the System Main
Screen, then choose Filters. This will display a list of alarm filters, as shown in Figure 11-1.

In this menu, use the arrow keys to highlight the first column of the SENSOR line. Pressing
<Enter> displays the options ignore, log, and report. The option chosen here will act as the
highest-level option for all alarm port sensors. If this variable is set to ignore, any alarm
conditions on the alarm port will be ignored
, even if you set them up individually to log or
report.

Likewise, if you set this variable to log, all sensors on the Alarm port that are set to anything
other than ignore will be logged but not reported. For this reason, it is crucial that the
SENSOR variable be set to report (see Figure 11-1). The following screen is the default alarm
filter settings that are set on the IMACS-200.

Figure 11-1.Alarm Filter Screen

11.2.2 Alarm Ports Main Screen

Figure 11-2 shows the Alarm level from the Main Screen. To go to this screen, highlight the
ALM area in the System Main Screen and press <Enter>.