Table 2-2 l, Table 2-3 – Zhone Technologies IMACS-200 User Manual

Page 32

Advertising
background image

2-6

System Installation

Model No.

Running Head

Connector Types

System Installation

Table 2-2. Front panel connectors

Connector Name

Connector Type

Description

Ethernet

RJ45

Ethernet port for remote management over IP.

Serial

RJ45

Asynchronous craft port for local management.

Table 2-3. Back panel connectors

Connector Name

Connector Type

Description

Voice

50 pin amphenol

Four E&M lines, transmit only (to) in the introductory offering of the
IMACS-200. Each line utilizes eight leads from the connector.

Voice

50 pin amphenol

Four FXS Tip-and-Ring pairs. Each line utilizes two leads from the
connector.

Voice

50 pin amphenol

Alarm input contacts are provided in this connector. There are four
available contacts, each utilizing two leads from the connector.

Alarm

RJ45

Alarm outputs to an external alarm system.

High Speed Data

DB25 female

Two V.35 high speed data port connectors.

Sub Rate Data

RJ45

Five subrate data (SRU) ports

OHSU1 and
OHSU2

Two ST optical
connector pairs

The IMACs-200 can be configured with an Optical High Speed Unit
with two pairs of optical connections.

Enet

RJ45

Ethernet port for remote management over IP. This port is disabled for
this initial release of the product.

T1/E1

RJ45

Four transmit and receive pairs for T1 network access. E1 will be
provided in a later release.

48VDC (+-G) 1.5A
Max

125VDC (label)

3 position

(plugs included
with kit of parts)

For DC power inputs. IMACS-200 can have two DC inputs.The
cables used to connect the power to the chassis should be 20 to 18
gauge solid wire.

120/220VAC

AC receptacles

Power input 1.0A 50/60Hz when external AC voltage is used to
power the unit.The IMACS-200 can have two such supplies.

OWAN1 OWAN2

Two ST optical
Connectors

The IMACs-200 can be configured with an Optical WAN Unit with
two optical connections.

Earth Ground

Permanent Earth Ground Connection.

Use 14 gauge solid wire for

a single connection to the provided earth ground screw, and
connect to a ground source.

Advertising