11-4

Alarm Ports

Model No.

Running Head

Alarm port User Screens and Settings

Alarm ports

Table 11-1. Alarm Contacts Main Screen Actions

Table 11-2. Alarm Contacts Settings and Defaults

SWITCH

The Switch setting indicates that the outbound alarm switch is actv (on) or stdby (off).

ACT ON

The Act On parameter defines the type of system alarm that will cause the switch to trigger.
Program each alarm switch to trigger on minor (information and minor) alarms, major (major
and critical) alarms, or any alarm message.

SENSOR

The Sensor setting indicates the inbound alarm sensor is actv (on) or stdby (off).

TRIG ON

The Trigger On parameter defines if the sensor should report an external alarm upon sensing
the opening (open) or the closure (close) of the external contact to which it is connected.

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated on screen (i.e., alarm data).

Main

Returns to the System Main Screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

SWITCH

stdby actv

stdby

ACT ON

minor major any

minor

SENSOR

stdby actv

stdby

TRIG ON

close open

close