2 voice diagnostics, Voice diagnostics -3 – Zhone Technologies IMACS-200 User Manual

Page 247

Advertising
background image

Diagnostics

14-3

System Testing and Diagnostics

User port Diagnostics

14.3.2 Voice Diagnostics

The software-initiated diagnostics supported are voice ports include the setting of both analog
and digital loopbacks toward the network and the generation of Quiet Tone and a Digital
MilliWatt signal on a port-by-port basis. The operator can also monitor and set the state of the
analog leads of any FXS or E&M port. They can set and monitor the state of the ABCD
signaling bits of the digitized voice signal. In cross-connect system, test functionality also
includes the ability to generate test tones (300Hz, 1 kHz and 3 kHz) and transmit those toward
the user side or the network side of the system. The table below shows detailed information
on the diagnostic capabilities of the Voice ports.

4-wire E&M 2-wire FXS

On-port loopbacks

Analog Toward Network

Yes

Yes

Digital Toward Network

Yes

Yes

Signaling Manipulation

Set Status of Analog Interface Leads

Yes

Yes

Set Transmit ABCD Signaling Bits

Yes

Yes

Set Receive ABCD Signaling Bits

Yes*

Yes*

Monitor Status of Analog Interface
Leads

Yes

Yes

Monitor Status of Transmit ABCD
Signaling Bits

Yes

Yes

Monitor Status of Receive ABCD
Signaling Bits

Yes

Yes

Tone Generation

Tone Supported

300 Hz

Yes*

Yes*

1 kHz

Yes*

Yes*

3 kHz

Yes*

Yes*

Quiet Tone

Yes

Yes

Digital MilliWatt

Yes

Yes

Tone Direction

Toward User

Yes

Yes

Toward Network

Yes

Yes

Advertising