Sub Rate Data Ports

Model No.

Running Head

Test Screen

SRU Ports

CTS

The Clear To Send (CTS) option allows you to define whether the CTS control lead should be
held on (high) or off (low). Selecting either on or off will override the selection made in the
SRU port screen. The third option is norm (normal) which means that CTS will behave as
described in Table 8-3.

RLSD

The Receive Level Signal Detect (RLSD) option allows you to define whether the RLSD
control lead should be held on (high) or off (low). The third option is norm (normal) which
means that RLSD will behave as described in Table 8-3.

SYNC

The Synchronization (SYNC) field tells you if the integrated BERT has achieved
synchronization either with itself via a remote loopback or with the remote test equipment.
Since this is an information-only field, there are no user-selectable parameters.

BE

The Bit Error field shows the total number of bit errors logged. Since this is an
information-only field, there are no user-selectable parameters.

ES

The Errored Seconds field shows the total number of seconds in which any errors were
detected. Since this is an information-only field, there are no user-selectable parameters.

SES

The Severely Errored Seconds (SES) field shows the total number of seconds in which the bit
error rate exceeded one bit per thousand (1 x 10

-3

). Since this is an information-only field, there

are no user-selectable parameters.

CSES

The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten
consecutive Severely Errored Seconds. Once triggered, the CSES field will increment (by
one) for each elapsed second until the system logs ten consecutive non-Severely Errored
Seconds. Since this it an information-only field there are no user-selectable parameters.