OHSU Ports

10-3

Table 10-1. OHSU port Main Screen Actions

Table 10-2. OHSU port Setting Options and Defaults

STATE

The State setting determines whether the port is active or inactive. An inactive port does not
occupy time slots on a WAN link. Set State to standby (stdby) for ports you are not using or
have not yet configured. Set it to active (actv) for ports that are ready for use.

WAN

The WAN setting identifies the WAN or OWAN port to which the output of this port is
directed. The options are wan-1 to wan-4, and owan-1 to owan-4.

MODE

The Mode parameter appears for information only. The OHSU is fixed in the MUX mode.

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e., performance and test data).

Main

Returns to the System Main Screen. If changes are made to settings and not
saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

STATE

stdby actv

stdby

WAN/SRV

none wan-1 wan-2 wan-3 wan-4
owan-1 owan-2 owan-3 owan-4

none

MODE

mux

mux

TS

table (up to 12 TS)

no assignment

RATE

64k 64k

TX CLOCK

int (mux MODE)

int

LOCAL LB

off user net

off