Zhone Technologies IMACS-200 User Manual

Page 199

Advertising
background image

High Speed Data Ports

9-11

Table 9-5. Test Screen Option Settings and Defaults

BERT

The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER)
on the selected HSU port. The patterns that can be selected are off, mark (1111), space (0000),
1:1 (1010 alternating), 1:7 (0100-0000), 3:24, qrss (quasi-random signal source),
prb11(pseudorandom binary sequence), prb15 and prb20.

SYNC

The Synchronization field indicates if the integrated BERT has achieved synchronization
either with itself via a remote loopback or with the remote test equipment. This is an
information-only field; it is not user-configurable.

BE

The Bit Error (BE) field indicates the total number of bit errors logged. This is an
information-only field; it is not user-configurable.

ES

The Errored Seconds (ES) field indicates the total number of seconds in which errors were
detected. This is an information-only field; it is not user-configurable.

Parameter

User Options

Notes

Default

BERT

off mark space 1:1 1:7 3:24 qrss prb11
prb15 prb20

off

DIR

net user

net

SYNC

information only–no user options

BE

information only–no user options

ES

information only–no user options

SES

information only–no user options

CSES

information only–no user options

OSS

information only–no user options

BER

information only–no user options

ELAP

information only–no user options

LB ST

information only–no user options

Advertising