System Configuration and Operation

Alarms

Table 3-2. Alarm Filters

WARNING!Alarm Modifiers

Each alarm may also be designated as I=info, m=minor, M=major or C=crit. The filter
modifier appears on both the active alarm and alarm history screens.

Filter

Alarm

Meaning

NOS

No Signal

Incoming WAN signal is lost.

LOS

Loss of Synchronization

Frame Alignment is lost.

YEL

Yellow Alarm

The system has received a Yellow Alarm signal from a remote device.
Usually received when the device loses WAN signal or synchronization.

AIS

Alarm Information Signal

The system has received a Blue Alarm signal from a remote device. Usually
received when the remote or intermediate device has a major failure.

CGA_RED

Carrier Group Alarm - Red

The local incoming WAN signal has a serious problem and trunk
conditioning is started. After receiving a RED alarm (NOS or LOS) for 2-3
seconds, the system initiates the appropriate trunk conditioning sequence
(see voice ports for information about the TC_CGA setting) and sends a
Yellow Alarm to the remote device. If the system is in drop/insert mode, it
also sends an AIS signal to the downstream equipment.

CGA_YEL

Carrier Group Alarm - Yellow

The system has initiated trunk conditioning in response to a Yellow Alarm
from a remote device. After 2-3 seconds, the system initiates the appropriate
trunk conditioning sequence (see voice ports for information about the
TC_CGA setting).

ERR

Excessive Error Rate

The error rate measured by the system has exceeded the threshold set on the
WAN port.

SENSOR

Alarm port Sensor

The Alarm port sensor has received an alarm indication from an attached
device.

HI-TEMP

Temperature Alarm

The IMACS-200 has exceeded it’s ability to regulate the temperature in the
unit, and external action is required.

FANFAIL

Cooling Fan Failure

One of the two supplied fans has failed.

UCA

User port/port alarm

One or more active ports on a user port are not working properly. Voice ports
will show an alarm for excessive signaling transitions and data ports will
show an alarm for exceeding the data error threshold.

RESET

System reset

The system has been reset by either loss of power or by a system software
upgrade.

ACO

Alarm Cut-Off

The ACO option forces you to manually clear certain alarms. Without this
option, self-correcting alarms might not be noticed. When the ACO option is
set to either Report or Log and the modifier is set to Major, alarms will report
normally but will also generate an ACO alarm. If the modifier is set to Minor,
it will not generate the ACO alarm. If the filter is set to Ignore, no alarms will
be generated. This can depend on whether or not the IMACS-200 is set for
latch or cur.

SYNC

Clock Sync Alarm

The SYNC alarm is generated when either the primary or secondary external
clock source is lost. This alarm is in addition to the condition that lost the
clock source (CGA-RED or OOS).