16 setting the bar graph display mode, 16 setting the bar graph display mode -27, 16 settng the bar graph dsplay mode – Yokogawa µR10000 User Manual

Page 210: App index

Advertising
background image

9-27

IM 04P01B01-01E

Operat

ons
Related

to

the
Computat

on

Funct

on

(/M1
Opt
on)

1

2

3

4

5

6

7

8

9

10

11

12

App

Index

9.16 Settng the Bar Graph Dsplay Mode

This section explains the details of setting the bar graph display mode.
Basic Setting mode cannot be entered when recording is in progress or when
computation is in progress on models with the computation function (/M1 option).

Procedure

Changng the Settngs

1.

Hold down the

MENU

key for 3 seconds to enter Setting mode.

2.

Hold down the

and

keys simultaneously for 3 seconds to enter Basic

Setting mode.

3.

Press the

key or

SHIFT +

key to select

Math and then press the key.

4.

Press the

key or

SHIFT +

key to select

Bar graph and then press the

key.

5.

Set each item and press the key.

Use the

key or

SHIFT +

key to select values.

For the procedure on how to enter values or characters, see section 4.2.
If you press the

ESC key in the middle of the operation, the settings entered up to

then are cancelled, and the display returns to a higher level menu.

6.

When the

Settng complete screen appears, do either of the following:

Press the key to set other channels.
If you are done, press the

ESC key.

Set the channel range.

The new setting takes effect.

ESC/?

Select the display mode of the bar

graph.

First channel Last channel

0A-0A Channel

Setting complete

Basic=Math

Math=Bar graph

CH=0A-0A

Graph=Normal

Applyng the Changes and Returnng to Operaton Mode

Press the

key or

SHIFT +

key to select

End and then press the key. Press

the

key to select

Store and then press the key. The changes are applied, and

the screen returns to Operation mode. If you select

Abort and press the key, the

changes are discarded, and the screen returns to Operation mode. Press the

ESC key to

return to the

Basc= screen.

Explanaton

Graph

Normal: Sets the base point of the bar graph to the left or right of the recording span

whichever is smaller in value.

Center: Sets the base point of the bar graph to the 50% position of the recording span.

Advertising