BigIron RX Series Configuration Guide

23

53-1002484-04

Managing management module redundancy

2

FIGURE 1

Active and standby management module file synchronization

The BigIron RX Series system allows you to do the following related to file synchronization:

Compare files on the active module with files on the standby module and immediately
synchronize any files that are different.

Immediately synchronize all files between the active and standby modules.

The following sections explain how to perform these tasks.

Comparing and synchronizing files

You can initiate a comparison of the flash code, system-config file, and running-config file on the
active management module with the same files on the standby module and synchronize the files
immediately if differences exist. When you synchronize the files, the active module copies its files
to the standby module, replacing the files on the standby module.

Synchronized at startup
or switchover

Also can be immediately
synchronized using the CLI

Startup-config also
automatically updated
with write memory
command

Automatically synchronized
at regular, user-configurable
intervals

Also can be immediately
synchronized using the CLI

Not synchronized

Active Management Module

Flash code

Startup-config file

Running-config file

Boot code

Standby Management Module

Flash code

Startup-config file

Running-config file

Boot code