Brocade BigIron RX Series Configuration Guide User Manual

Page 1454

Advertising
background image

1376

BigIron RX Series Configuration Guide

53-1002484-04

Continuous system monitor overview

52

--- Event TM Reg (Enabled) ---

Threshold: 1 / 10, FAP Shutdown: Allowed

Reg 0440: monitor mask 00fefbff, fap shutdown mask 003e0000, syslog mask 003e0000,

log backoff number 1800

FAP shutdown threshold (non-zero only): bit17-1 bit18-1 bit19-1 bit20-1 bit21-1

Reg 0444: monitor mask 0007f8c7, fap shutdown mask 0007e001, syslog mask 0007e001,

log backoff number 1800

FAP shutdown threshold (non-zero only): bit0-1 bit4-1 bit13-1 bit14-1 bit15-1

bit16-1 bit17-1 bit18-1

Reg b900: monitor mask 00000003, fap shutdown mask 00000000, syslog mask 00000000,

log backoff number 1800

FAP shutdown threshold (non-zero only):

Reg 9880: monitor mask 00000003, fap shutdown mask 00000000, syslog mask 00000000,

log backoff number 1800

FAP shutdown threshold (non-zero only):

Reg 2838: monitor mask 003f8000, fap shutdown mask 00000000, syslog mask 00000000,

log backoff number 1800

FAP shutdown threshold (non-zero only):

Reg 2830: monitor mask ffffffff, fap shutdown mask 00000000, syslog mask 00000000,

log backoff number 1800

FAP shutdown threshold (non-zero only):

----------------------------------

--- Event NP TCAM (Enabled) ---

----------------------------------

--- Event TM Q Scanner (Enabled) ---

Threshold: 4 / 10, Log Backoff Number: 1800

Action:

----------------------------------

--- Event NP PACKET (Enabled) ---

Threshold: 5 / 10, Log Backoff Number: 1800

Action:

----------------------------------

--- Event TM Tx Buffer (Enabled) ---

Threshold: 1 / 10, Log Backoff Number: 1800

Action: REINIT_FAP

----------------------------------

--- Event TM DRAM CRC (Enabled) ---

DRAM CRC Count Threshold: 2, Log Backoff Number: 1800

Action: SHUTDOWN

----------------------------------

--- Event LPM Error (Enabled) ---

Threshold: 1 / 10, Log Backoff Number: 1800

Action: SYSLOG

----------------------------------

--- Event FE Link (Enabled) ---

Threshold: 5 / 10, Log Backoff Number: 1800

Action: SHUTDOWN_LINK

----------------------------------

--- Event FE FIFO Overflow (Enabled) ---

Threshold: 5 / 10, Log Backoff Number: 1800

Action: