Layer 2 enhancements – Brocade BigIron RX Series Configuration Guide User Manual

Page 66

Advertising
background image

lxvi

BigIron RX Series Configuration Guide

53-1002484-04

Layer 2 enhancements

Enhanced Digital
Optical Monitoring

You can configure the BigIron RX to monitor XFPs and SFPs in
the system either globally or by specified port.

Book: Brocade BigIron RX
Series Hardware
Installation Guide
Chapter: Connecting a
BigIron RX Series Switch
to a Network Device
Section: Enhanced Digital
Optical Monitoring

Re-distributing CAM
Allocations

In releases prior to 02.3.00, CAM partitioning was not
configurable. Starting in BigIron RX software release 02.3.00,
you can specify the CAM assigned to each of the CAM entry
types globally.

Book: BigIron RX Series
Configuration Guide
Chapter:

“Configuring

Basic Parameters”

Section:

“Re-distributing

CAM allocations”

Enhanced SFM
(power-off)
command

You can disable power to a specified switch fabric module and
then reenable it.

Book: Brocade BigIron RX
Series Hardware
Installation Guide
Chapter: Managing the
BigIron RX Series Chassis
and Modules
Section: Disabling and
Reenabling Power to the
Switch Fabric Modules

Enhanced
speed-duplex
command

In this release, the speed-duplex command has been
enhanced to include the master and slave parameters.

Book: BigIron RX Series
Configuration Guide
Chapter:

“Configuring

Interface Parameters”

Section:

“Speed/Duplex

negotiation”

TABLE 17

Layer 2 enhancements

Enhancement

Description

See...

Flow based MAC Learning

In this release, the cpu-flooding unknown-unicast
command that disables hardware flooding of
unknown unicast on every VLAN has been added.
This will allow MAC learning only where necessary
and at a system level to allow more than 16k MACs.

Book: BigIron RX Series
Configuration Guide
Chapter:

“VLANs”

Section:

“Flow based

MAC learning”

TABLE 16

System enhancements (Continued)

Enhancement

Description

See...

Advertising