Displaying VSRP information

15

This display shows the following information when you use the vrid <num> or vlan <vlan-id>
parameter. For information about the display when you use the aware parameter, refer to

“Displaying the active interfaces for a VRID”

on page 450.

TABLE 90

CLI display of VSRP VRID or VLAN information

This field...

Displays...

Total number of VSRP routers defined

The total number of VRIDs configured on this device.

VLAN

The VLAN on which VSRP is configured.

auth-type

The authentication type in effect on the ports in the VSRP VLAN.

VRID parameters

VRID

The VRID for which the following information is displayed.

state

This device’s VSRP state for the VRID. The state can be one of the
following:

initialize – VSRP is not enabled on the VRID. If the state remains
“initialize” after you enable VSRP on the VRID, make sure that the
VRID is also configured on the other routers and that the routers
can communicate with each other.

NOTE: If the state is “initialize” and the mode is incomplete, make sure

you have specified the IP address for the VRID.

standby – This device is a Backup for the VRID.

master – This device is the Master for the VRID.

Administrative-status

The administrative status of the VRID. The administrative status can be
one of the following:

disabled – The VRID is configured on the interface but VSRP or
VRRPE has not been activated on the interface.

enabled – VSRP has been activated on the interface.

Advertise-backup

Whether the device is enabled to send VSRP Hello messages when it is a
Backup. This field can have one of the following values:

disabled – The device does not send Hello messages when it is a
Backup.

enabled – The device does send Hello messages when it is a
Backup.

Preempt-mode

Whether the device can be pre-empted by a device with a higher VSRP
priority after this device becomes the Master. This field can have one of
the following values:

disabled – The device cannot be pre-empted.

enabled – The device can be pre-empted.

save-current

The source of VSRP timer values preferred when you save the
configuration. This field can have one of the following values:

false – The timer values configured on this device are saved.

true – The timer values most recently received from the Master are
saved instead of the locally configured values.

NOTE: For the following fields:

Configured – indicates the parameter value configured on this device.

Current – indicates the parameter value received from the Master.

Unit – indicates the formula used tor calculating the VSRP priority and the timer scales in effect for the VSRP
timers. A timer’s true value is the value listed in the Configured or Current field divided by the scale value.