To associate the primary and secondary storage systems and then configure logical paths between
the two storage systems, both the primary storage system administrator and the secondary storage
system administrator must perform this operation:

1.

Make sure the remote copy connections and ports are properly configured. Also, get the serial
number of the remote storage system.

NOTE:

To get the serial number of the remote storage system, ask the administrator of the

remote storage system. The serial number will be displayed in the Remote Web Console main
window when the Remote Web Console user logs into the storage system.

2.

Ensure that the Remote Web Console main window is in Modify mode.

For detailed information about how to do this, see the HP XP24000/XP20000 Remote Web
Console User's Guide
.

3.

Ensure that the DKC Operation window is displayed.

4.

In Display, select DKC.

5.

Select LDKC from the tree.

6.

Right-click the upper-right list, and then select DKC Operation and Add DKC

The Add DKC window appears (see

Figure 65 (page 144)

).

7.

In the Add DKC window, enter the following information:

The serial number of the remote storage system

The LDKC number of the remote storage system. When the remote storage system is an
XP12000/XP10000 or XP24000/XP20000 Disk Array, “00” appears.

The controller ID of the remote storage system (model name that indicates the model)

NOTE:

The controller ID for an XP24000/XP20000 storage system is

5(XP24000/XP20000).

The path group ID

The path group ID is within the range of 1-FF (hexadecimal). Up to 64 path group IDs
can be registered per storage system.

NOTE:

In the current version, the path group ID always takes the default value and

cannot be changed.

8.

In the Add DKC window, select a primary storage system port and a remote storage system
port to configure a logical path.

9.

Click Option.

10.

In the DKC Option window, configure logical path options and storage system options.

For detailed information about the options, see the next section and read the explanations
below

“DKC Option Window” (page 146)

.

11.

Click Set to close the DKC Option window.

12.

See the Preview list to check the settings that you have made.

To modify a setting, select and right-click the setting from the Preview list and then select
Modify. A window appears and allows you to modify the setting.

To cancel a setting, select and right-click the setting in the Preview list and then select
Cancel.

13.

Click Apply to apply the settings that you have made.