HP StorageWorks XP Remote Web Console Software User Manual

Page 45

Advertising
background image

3

In the case of an XP20000 Disk Array, the name of the package location is 1H.

4

In the case of an XP20000 Disk Array, the name of the package location is 1A.

Table 10 SAID Values for the PATH LINK Parameter (REAR CL2)

SAID

Port

Package

Location

SAID

Port

Package

Location

SAID

Port

Package

Location

SAID

Port

Package

Location

X'0094'

CLA-E

2NU

X'009C'

CLA-N

2WU

X'0018'

CL2-J

2TU

X'0010'

CL2-A

2QU

2

1

X'00B4'

CLC-E

(Add14)

X'00BC'

CLC-N

(Add10)

X'0038'

CL4-J

(Add4)

X'0030'

CL4-A

(Basic)

X'00D4'

CLE-E

X'00DC'

CLE-N

X'0058'

CL6-J

X'0050'

CL6-A

X'00F4'

CLG-E

X'00FC'

CLG-N

X'0078'

CL8-J

X'0070'

CL8-A

X'0095'

CLA-F

X'009D'

CLA-P

X'0019'

CL2-K

X'0011'

CL2-B

X'00B5'

CLC-F

X'00BD'

CLC-P

X'0039'

CL4-K

X'0031'

CL4-B

X'00D5'

CLE-F

X'00DD'

CLE-P

X'0059'

CL6-K

X'0051'

CL6-B

X'00F5'

CLG-F

X'00FD'

CLG-P

X'0079'

CL8-K

X'0071'

CL8-B

X'0096'

CLA-G

2NL

X'009E'

CLA-Q

2WL

X'001A'

CL2-L

2TL

X'0012'

CL2-C

2QL

X'00B6'

CLC-G

(Add12)

X'00BE'

CLC-Q

(Add8)

X'003A'

CL4-L

(Add6)

X'0032'

CL4-C

(Add2)

X'00D6'

CLE-G

X'00DE'

CLE-Q

X'005A'

CL6-L

X'0052'

CL6-C

X'00F6'

CLG-G

X'00FE'

CLG-Q

X'007A'

CL8-L

X'0072'

CL8-C

X'0097'

CLA-H

X'009F'

CLA-R

X'001B'

CL2-M

X'0013'

CL2-D

X'00B7'

CLC-H

X'00BF'

CLC-R

X'003B'

CL4-M

X'0033'

CL4-D

X'00D7'

CLE-H

X'00DF'

CLE-R

X'005B'

CL6-M

X'0053'

CL6-D

X'00F7'

CLG-H

X'00FF'

CLG-R

X'007B'

CL8-M

X'0073'

CL8-D

X'0090'

CLA-A

2MU

X'0098'

CLA-J

2XU

X'001C'

CL2-N

2UU

X'0014'

CL2-E

2RU

4

3

X'00B0'

CLC-A

(Add15)

X'00B8'

CLC-J

(Add11)

X'003C'

CL4-N

(Add5)

X'0034'

CL4-E

(Add1)

X'00D0'

CLE-A

X'00D8'

CLE-J

X'005C'

CL6-N

X'0054'

CL6-E

X'00F0'

CLG-A

X'00F8'

CLG-J

X'007C'

CL8-N

X'0074'

CL8-E

X'0091'

CLA-B

X'0099'

CLA-K

X'001D'

CL2-P

X'0015'

CL2-F

X'00B1'

CLC-B

X'00B9'

CLC-K

X'003D'

CL4-P

X'0035'

CL4-F

X'00D1'

CLE-B

X'00D9'

CLE-K

X'005D'

CL6-P

X'0055'

CL6-F

X'00F1'

CLG-B

X'00F9'

CLG-K

X'007D'

CL8-P

X'0075'

CL8-F

X'0092'

CLA-C

2ML

X'009A'

CLA-L

2XL

X'001E'

CL2-Q

2UL

X'0016'

CL2-G

2RL

X'00B2'

CLC-C

(Add13)

X'00BA'

CLC-L

(Add9)

X'003E'

CL4-Q

(Add7)

X'0036'

CL4-G

(Add3)

X'00D2'

CLE-C

X'00DA'

CLE-L

X'005E'

CL6-Q

X'0056'

CL6-G

X'00F2'

CLG-C

X'00FA'

CLG-L

X'007E'

CL8-Q

X'0076'

CL8-G

X'0093'

CLA-D

X'009B'

CLA-M

X'001F'

CL2-R

X'0017'

CL2-H

X'00B3'

CLC-D

X'00BB'

CLC-M

X'003F'

CL4-R

X'0037'

CL4-H

X'00D3'

CLE-D

X'00DB'

CLE-M

X'005F'

CL6-R

X'0057'

CL6-H

X'00F3'

CLG-D

X'00FB'

CLG-M

X'007F'

CL8-R

X'0077'

CL8-H

XP for Business Continuity Manager Software Support

45

Advertising