Using parameter copy function – IDEX Health & Science VS-606V7 Series User Manual

Page 116

Advertising
background image

116

Using Parameter Copy Function

The VS-606V7 standard digital operator JVOP-140 can store parameters for one
inverter. A backup power supply is not necessary since EEPROM is used.

Parameter copy function is possible only for the inverters with the same product series,
power supply specifications and control mode (V/f control or vector control).

However, some parameters may not be copied. It is also impossible to copy parameters
between VS-606V7 and VSmini J7 inverters.

The prohibition of the reading of parameters from the inverter can be set at n177. The
parameter data cannot be changed when this parameter is set.

If any alarm occurs during parameter copy, the PRGM will blink and copying will
continue.

Parameter Copy Function Selection (n176)

Depending on the setting of n176 for parameter copy function selection, the following
functions are available:

1. Read all the parameters from the inverter (READ) and store them in EEPROM in the

digital operator.

2. Copies the parameters stored in the digital operator to the inverter (COPY).

3. Verify that the parameters in the digital operator and the parameters in the inverter

are the same (VERIFY).

4. Displays the maximum applicable motor capacity and the voltage class of the

inverter that has the parameters stored in the digital operator.

5. Displays the software number of the inverter that has the parameters stored in the

digital operator.

Parameter copy function