Initial setting

Terminal function at 3-wire sequence selection

When 0 is set at the terminal S3 (n052), terminal S1 becomes run command, terminal
S2 becomes stop command, and terminal S3 becomes FWD/REV run command.

LOCAL/REMOTE select (setting: 17)
Select operation reference either by the digital operator or by the settings of
operation method selection (n003) and frequency reference selection (n004).
LOCAL/REMOTE select is available only during stop.

Open:

Run according to the setting of run command selection (n003) or
frequency reference selection (n004)

Closed: Run by frequency reference and run command from the digital operator.

No.

Terminal

Initial Setting

Function

n050

S1

1

Forward run command (2-wire sequence)

n051

S2

2

Reverse run command (3-wire sequence)

n052

S3

3

External fault

n053

S4

5

Fault reset

n054

S5

6

Multi-step speed reference 1

n055

S6

7

Multi-step speed reference 2

n056

S7

10

JOG command