Standard Specifications (400V Class)

Voltage Class

400V 3-phase

Model

CIMR-V7*C

‰‰‰‰

3-phase

40P2 40P4 40P7 41P5 42P2 43P0 43P7 45P5 47P5

Single-phase

Max. Applicable Motor Output HP

(kW)*

0.5

(0.2)

0.75
(0.4)

2

(0.75)

3

(1.5)

3

(2.2)

3

(3.0)

5

(3.7)

7.5

(5.5)

10

(7.5)

Out

put

Charac

te

ri

s

ti

c

s

Inverter Capacity (kVA)

0.9

1.4

2.6

3.7

4.2

5.5

7.0

11

14

Rated Output Current (A)

1.2

1.8

3.4

4.8

5.5

7.2

9.2

14.8

18

Max. Output Voltage (V)

3-phase, 380 to 460V (proportional to input voltage)

Max. Output

Frequency (Hz)

400 Hz (Programmable)

Input

Current (A)

(3-Phase)

1.6

2.4

4.7

7.0

8.1

10.6

12.0

19.6

23.8

Po

w

e

r

S

uppl

y

Rated Input Voltage

and Frequency

3-phase, 380 to 460V, 50/60Hz

Allowable Voltage

Fluctuation

-15 to +10%

Allowable Frequency

Fluctuation

±

5%

Cont

rol

Charac

te

ri

s

ti

c

s

Control Method

Sine wave PWM (V/f control/voltage control selectable)

Frequency Control Range

0.1 to 400Hz

Frequency Accuracy

(Temperature Change)

Digital reference:

±

0.01%, 14 to 122

°

F (-10 to +50

°

C)

Analog reference:

±

0.5%, 59 to 95

°

F (25

±

10

°

C)

Frequency Setting Resolution

Digital reference: 0.01Hz (less than 100Hz) / 0.1Hz (100Hz
or more)
Analog reference: 1 / 1000 of max. output frequency

Output Frequency

Resolution

0.01Hz

Overload Capacity

150% rated output current for one minute

Frequency Reference

Signal

0 to 10VDC (20k

), 4 to 20mA (250

), 0 to 20mA (250

)

pulse train input, frequency setting potentiometer
(Selectable)

Accel/Decel Time

0.00 to 6000 sec. (accel/decel time are independently
programmed)

Braking Torque

Short-term average deceleration torque‡
0.2kW: 150%
0.75kW: 100%
2HP (1.5kW): 50%
3HP (2.2kW) or more: 20%
Continuous regenerative torque: Approx. 20% (150% with
optional braking resistor, braking transistor built-in)

V/f Characteristics

Possible to program any V / f pattern

* Based on a standard 4-pole motor for max. applicable motor output.

Shows deceleration torque for uncoupled motor decelerating from 60Hz
with the shortest possible deceleration time.