IDEX Health & Science VS-606V7 Series User Manual

Page 138

Advertising
background image

138

Alarm Display

Inverter

Status

Explanation

Causes and

Corrective Actions

Digital

Operator

RUN(Green)

ALARM(RED)

Stops
according to
parameter.

STP (Emergency stop)
The inverter stops according
to parameter n005 after
receiving the emergency stop
fault signal.

Check the external
circuit (sequence).

FBL (PID feedback loss
detection)
PID feedback value drops
below the detection level.
When PID feedback loss is
detected, the inverter
operates according to the
n136 setting.

Check the mechanical
system and correct the
cause, or increase the
value of n137.

Fault Display

Inverter

Status

Explanation

Causes and

Corrective Actions

Digital

Operator

RUN(Green)

ALARM(RED)

Option card communications
fault.
Communication fault has
occurred in a mode that run
command and frequency
reference are set from the
communication option card.

Check the
communications
devices or
communication signals.

_

(OFF)

Insufficient power supply

voltage

• Control power supply fault.

Hardware fault

Check the following:

Power supply

voltage

• Main circuit power

supply wiring is
connected

Terminal screws are

securely tightened

Control sequence.

Replace the
inverter.