Example of 200v class motor – IDEX Health & Science VS-606V7 Series User Manual

Page 91

Advertising
background image

91

General-purpose motor and inverter duty motor
Induction motors are classified as general-purpose motors or inverter motors, based
on their cooling capabilities. Therefore, the motor overload function operates
differently between these two motor types.

Example of 200V class motor

Cooling Effect

Torque Characteristics

Electronic Thermal
overload

General

-p

urpos

e M

o

to

r

Effective when operated
at 50/60Hz from
commercial power
supply

Base Frequency 60Hz

(V/f for 60Hz, 220V Input Voltage)

For low-speed operation, torque must be
limited in order to stop motor temperature
rise.

error (motor

overload protection)
occurs when
continuously operated at
50/60Hz or less at 100%
load.

In

ve

rt

e

r M

o

to

r

Effective even when
operated at low speed
(approx. 6Hz)

Base Frequency 60Hz

(V/f for 60Hz, 220V Input Voltage)

Use an inverter motor for continuous
operation at low speed.

Electronic thermal
overload protection not
activated even when
continuously operated at
50/60Hz or less at 100%
load.

Advertising