• Monitoring

Following items can be monitored by U-parameter

parameter

No.

Name

Description

U-01

Frequency reference

(FREF)*

¹

Hz

Frequency reference can be monitored.
(Same as FREF)

U-02

Output frequency

(FOUT)*

¹

Hz

Output frequency can be monitored.
(Same as FOUT)

U-03

Output current

(IOUT)*

¹

Hz

Output current can be monitored.
(Same as IOUT)

U-04

Output voltage

V

Output voltage can be monitored.

U-05

DC voltage

V

Main circuit DC voltage can be monitored.

U-06

Input terminal status*

2

Input terminal status of control circuit terminals can be
monitored.

U-07

Output terminal status*

2

Output terminal status of control circuit terminals can
be monitored.

U-08

Torque monitor

%

The amount of output torque can be monitored. When
V/f control mode is selected, “----” is displayed.

U-09

Fault history (last 4 faults)

Last four fault history is displayed.

U-10

Software No.

Software No. can be checked.

U-11

Output power*

3

kW Output power can be monitored

U-13

Cumulative operation time*

4

x10H

Cumulative operation time can be monitored in units of
10H

U-15

Data reception error*

4

Contents of MEMOBUS communication data reception
error can be checked. (contents of transmission
register No. 003DH are the same)

U-16

PID feedback*

5

%

Input 100(%) / Max. output frequency or equivalent

U-17

PID input*

5

%

+ 100(%) /+ Max. output frequency

U-18

PID output*

5

%

+ 100(%) /+ Max. output frequency

*1 The status indicator LED is not turned ON.


*2 Refer to the next page for input / output terminal status.




*3 The display range is from -99.9kW to 99.99kW.
When regenerating. the output power will be displayed in units of 0.01kW when
-9.99kW or less and in units of 0.1kW when more than -9.99kW.
When in the vector control mode, “----” will be displayed.
*4 This function only applies to 200/400V class 7.5/10hp (5.5/7.5kW) inverters.
*5 Displayed in units of 0.1% when less than 100% and in units of 1% when 100% or
more. The display range is from -999% to 999%.