9. Specifications

Standard Specifications (200V Class)

Voltage Class

200V single- / 3-phase

Model

CIMR-V7*C

‰‰‰‰

3-phase

20P1 20P2 20P4 20P7 21P5 22P2 23P7 25P5 27P5

Single-phase

B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B3P7

-

-

Max. Applicable Motor Output kW*

0.1

0.25

0.55

1.1

1.5

2.2

3.7

5.5

7.5

Ou

tp

u

t

Ch

arac

te

ri

s

ti

c

s

Inverter Capacity (kVA)

0.3

0.6

1.1

1.9

3.0

4.2

6.7

9.5

13

Rated Output Current (A)

0.8

1.6

3

5

8

11

17.5

25

33

Max. Output Voltage (V)

3-phase, 200 to 230V (proportional to input voltage)
Single-phase, 200 to 240V (proportional to input voltage)

Max. Output Frequency (Hz)

400 Hz (Programmable)

Input

Current (A)

(3-Phase)

1.1

1.9

3.9

6.4

11.0

15.1

24.0

33.0

39.6

(Single-Phase)

1.8

3.7

7.4

12.8

20.5

24.0

40.0

-

-

Po

w

e

r

S

uppl

y

Rated Input Voltage and

Frequency

3-phase, 200 to 230V, 50/60Hz
Single-phase, 200 to 240V, 50/60Hz

Allowable Voltage Fluctuation

-15 to +10%

Allowable Frequency Fluctuation

±

5%

Co

nt

rol

Charac

te

ri

s

ti

c

s

Control Method

Sine wave PWM (V/f control/voltage control selectable)

Frequency Control Range

0.1 to 400Hz

Frequency Accuracy

(Temperature Change)

Digital reference:

±

0.01% (-10 to +50

°

C)

Analog reference:

±

0.5% (25

±

10

°

C)

Frequency Setting Resolution

Digital reference:
0.01Hz (less than 100Hz) / 0.1Hz (100Hz or more)
Analog reference: 1 / 1000 of max. output frequency

Output Frequency Resolution

0.01Hz

Overload Capacity

150% rated output current for one minute

Frequency Reference Signal

0 to 10VDC (20k

), 4 to 20mA (250

), 0 to 20mA (250

)

pulse train input, frequency setting potentiometer
(Selectable)

Accel/Decel Time

0.00 to 6000 sec.
(accel/decel time are independently programmed)

Braking Torque

Short-term average deceleration torque‡
0.1, 0.25kW (0.13HP, 0.25HP): 150%
0.55, 1.1kW (0.5 HP, 1HP): 100%
1.5kW (2HP): 50%
2.2kW(3HP) or more: 20%
Continuous regenerative torque: Approx. 20% (150% with
optional braking resistor, braking transistor built-in)

V/f Characteristics

Possible to program any V/f pattern

*

Based on a standard 4-pole motor for max. applicable motor output.

Shows deceleration torque for uncoupled motor decelerating from 60Hz
with the shortest possible deceleration time.